Accident Summary Nr: 14427124 - Three burned, one later dies, when vulcanizer opens

Accident Summary Nr: 14427124 -- Report ID: 0830500 -- Event Date: 08/07/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10158810109/22/198630690Gates Rubber Co., Inc.

Abstract: Employees #1, a vessel operator, Employee #2, an electrician, and Employee #3, a pipefitter, began the day shift by checking the operation of the vulcanizer, a pressure vessel that hardens rubber with steam. The operator on the previous shift had reported that the machine was malfunctioning: it was not achieving the 370 degree F temperature required for the process, and it was filling with water during the initial steam cycle and not curing the rubber. When Employee #1 started the steam cycle, the vessel malfunctioned as described, and the crew decided to abort the cycle. Employee #1 pressed the EMERGENCY STOP button, initiating a circuit that caused the vulcanizer to open 43 seconds later. Employees #1 through #3, who were standing in front of the vessel, were burned by the hot water and steam that was released. Employee #1 died 1 1/2 months after the accident from his burns and ensuing medical complications. Employees #2 and #3 sustained less severe burns; neither was hospitalized. The workers were not aware of the exact timing of the circuitry, and the vulcanizer did not have a safety device to prevent it from opening.

Keywords: BURN, PRESSURE VESSEL, UNSECURED, WORK RULES, STEAM, UNTRAINED, MECH MALFUNCTION, HIGH TEMPERATURE, HOT WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101588101 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 101588101 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 101588101 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.