Accident Summary Nr: 14419360 - Employee suffers chemical burns to eye after tank explodes

Accident Summary Nr: 14419360 -- Report ID: 0728900 -- Event Date: 08/30/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10138179608/30/199028730Arcadian Corporation

Abstract: At about 2:00 a.m. on October 15, 1990, Employee #1 was transferring an approximately 20 percent monoethanolamine (ethanolamine) solution from a process vessel, the amine regenerator, to the top of an 11,000 gallon aluminum storage tank. The ethanolamine solution had apparently entrained hydrogen gas, some of which released to the atmosphere of the storage tank upon transfer and apparently caused the hydrogen gas concentration in the tank to exceed 4 percent. A source of ignition, possibly the static charge of the falling ethanolamine solution, caused the hydrogen to explode. Employee #1 was engulfed in the release of ethanolamine solution from the ruptured tank and sustained chemical burns to his left eye. The storage tank was damaged beyond repair, and piping, valves, and windows in the immediate area were destroyed. Damage was estimated at $70,000.

Keywords: EYE, CAUSTIC, FLAMMABLE VAPORS, PPE, WORK RULES, EXPLOSION, CHEMICAL REACTION, CHEMICAL BURN, CHEMICAL VAPOR, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101381796 Non Hospitalized injury Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close