Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14413140 - Employee killed when personnel basket falls

Accident Summary Nr: 14413140 -- Report ID: 0627400 -- Event Date: 06/28/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
144918007/06/198415420Empire Construction Co

Abstract: A hydraulic crane was being used to lower a personnel basket carrying Employee #1 into the receiving leg of a feed lot. As the basket descended into the leg, it became caught on the side of the leg. This caused the crane's hook to slip out of the lifting eye of the basket, allowing it to fall 100 ft. Employee #1 died of injuries sustained in the fall.

Keywords: PERSONNEL CAGE, CRANE HOOK, UNSECURED, WORK RULES, CAUGHT BY, CONSTRUCTION, FALL, HYDRAULIC CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1449180 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.