Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14408785 - Employee killed when struck by crane boom

Accident Summary Nr: 14408785 -- Report ID: 0626700 -- Event Date: 04/22/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12364994904/26/199716290Bench Company, Inc.

Abstract: A rough-terrain hydraulic truck crane was hauling a load of cross-ties when it tipped over. Its boom struck and killed Employee #1.

Keywords: CRANE BOOM, TRUCK CRANE, CONSTRUCTION, STRUCK BY, HYDRAULIC CRANE, OVERTURN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Contractor's yard/facility Other $20,000,000 and over X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 123649949 Fatality Other Helpers, construction trades Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Other Activities-Installing Ornamental And Archite
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close