Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14402226 - Employee killed when pinned under storage tank

Accident Summary Nr: 14402226 -- Report ID: 0626000 -- Event Date: 05/19/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10065431805/20/198742130The Transport Company Of Texas

Abstract: Employee #1, a truck operator, was unloading 3,900 gallons of caustic soda from a tanker trailer into a 6,000 gallon horizontal storage tank. The storage tank exploded and fell off its supports, pinning Employee #1. His leg was amputated and he bled to death. Employee #1 was working alone at the time of the accident.

Keywords: AMPUTATED, LOSS OF BLOOD, UNSECURED, PINNED, WORK RULES, STORAGE TANK, EXPLOSION, FALLING OBJECT, LEG, TRUCK DRIVER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100654318 Fatality Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.