Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14401913 - EMPLOYEE BREATHED NITROGEN SUPPLIED BY AIR LINE RESPIRATOR

Accident Summary Nr: 14401913 -- Report ID: 0626000 -- Event Date: 07/17/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
229841207/18/198517990Roy Hunt Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
229843807/19/198529110Koch Refining Company

Abstract: A PETROCHEMICAL REFINERY WAS UNDERGOING TURNAROUND. A CONTRACTOR CREW HAD BEEN ASSIGNED THE JOB OF SANDBLASTING THE INSIDE SURFACES OF A REACTOR VESSEL (CONFINED SPACE). ALTHOUGH UNWRITTEN COMPANY POLICY CALLED FOR THE USE OF AIR COMPRESSORS FOR SUPPLYING RESPIRATOR AIR, THIS CREW, WITH THE SUPERVISOR'S KNOWLEDGE, HAD PREVIOUSLY USED PLANT AIR TO SUPPLY BREATHING AIR. THE CREW MISTAKENLY HOOKED UP AN AIR FILTER TO AN UNLABELED NITROGEN LINE (ONLY THE SHUTOFF VALVE WAS LABELED) USED BY THE REFINEREY FOR PURGING CONFINED SPACES. PLANT NITROGEN LINES AND AIR LINES WERE IDENTICAL AND BOTH HAVE CROW'S FOOT COUPLINGS COMPATIBLE WITH THE COUPLING ON THE AIR FILTER. EMPLOYEE #1 CLIMBED TO THE BOTTOM OF THE VESSEL, PLACED THE SANDBLAST RESPIRATOR HOOD ON HIS HEAD AND BEGAN SANDBLASTING. HE WAS ASPHYXIATED WITHIN FIVE MINUTE'S TIME. ATTEMPTS TO REVIVE EMPLOYEE # WITH OXYGEN FAILED.

Keywords: OXYGEN DEFICIENCY, AIR LINE RESPIRATOR, ASPHYXIATED, WORK RULES, SANDBLASTING, CONFINED SPACE, NITROGEN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2298412 Fatality Asphyxia Construction trades, n.e.c.
2 2298438 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close