Accident Summary Nr: 14400451 - ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC SAW

Accident Summary Nr: 14400451 -- Report ID: 0626300 -- Event Date: 11/26/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
10179576312/02/198517510Jerry Stacey Construction

Abstract: AN EMPLOYEE WAS USING A TABLE SAW TO RIP CUT SOME 2-BY-4 STUDS. THE GROUND WAS SOAKED FROM RAIN THE PREVIOUS EVENING. THE CIRCUIT WAS RUN FROM THE POWER POLE TO A HOUSEHOLD-TYPE SWITCH ON THE SAW FRAME. BARE CONDUCTORS INSIDE THE SWITCH BOX WERE TOUCHING THE FRAME OF THE BOX. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: ELECTRICAL, ELECTROCUTED, ELECTRIC SAW, E C, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC CONDUCTOR, ELECTRICAL BOX

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101795763 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.