Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14398671 - Sixteen employees hospitalized for CO inhalation

Accident Summary Nr: 14398671 -- Report ID: 0626600 -- Event Date: 05/14/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10076550205/09/199120920Fisherman'S Reef Shrimp Plant Co.

Abstract: At approximately 9:00 a.m. on May 9,1991, employees at Fisherman's Reef Shrimp Co. were evacuated from the processing area due to inhalation of what were later determined to be high levels of carbon monoxide. The source of the carbon monoxide was three Clark forklifts. Thirty-three employees were transported to three area hospitals. Employees #1 through #16 required from overnight and to two days of hospitalization.

Keywords: OXYGEN DEFICIENCY, VENTILATION, AIR CONDITIONER, WORK RULES, INHALATION, INDUSTRIAL TRUCK, EXHAUST FUMES, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100765502 Hospitalized injury Asphyxia Occupation not reported
2 100765502 Hospitalized injury Asphyxia Occupation not reported
3 100765502 Hospitalized injury Asphyxia Occupation not reported
4 100765502 Hospitalized injury Asphyxia Occupation not reported
5 100765502 Hospitalized injury Asphyxia Occupation not reported
6 100765502 Hospitalized injury Asphyxia Occupation not reported
7 100765502 Hospitalized injury Asphyxia Occupation not reported
8 100765502 Hospitalized injury Asphyxia Occupation not reported
9 100765502 Hospitalized injury Asphyxia Occupation not reported
10 100765502 Hospitalized injury Asphyxia Occupation not reported
11 100765502 Hospitalized injury Asphyxia Occupation not reported
12 100765502 Fatality Asphyxia Occupation not reported
13 100765502 Hospitalized injury Asphyxia Occupation not reported
14 100765502 Hospitalized injury Asphyxia Occupation not reported
15 100765502 Hospitalized injury Asphyxia Occupation not reported
16 100765502 Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.