Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14398598 - BURN - ELECTRICAL FAULT IN ELECTRIC GRINDER

Accident Summary Nr: 14398598 -- Report ID: 0626600 -- Event Date: 02/14/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
10075778002/19/199134710Fin-Tech, Inc.

Abstract: Employee was grinding the inside of a steel pipe with an electric grinder. The grinder had an internal ground fault that energized its case. The extension cord set for the grinder was connected to a receptacle that had an intermittent ground because of a loose box and cover. The employee was electrocuted.

Keywords: E GI V, RECEPTACLE, ELECTRICAL, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRICAL BOX, ELEC PORT TOOL--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100757780 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.