Accident Summary Nr: 14394290 - Two employees killed, one hospitalized after tank entry

Accident Summary Nr: 14394290 -- Report ID: 0625700 -- Event Date: 11/14/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10147673708/15/198837310Southern Shipbuilding Corporation

Abstract: Employees #1 and #2 were preparing a hopper barge on a marine railway in a shipyard for its biennial Coast Guard inspection. While opening up the tank's manhole covers, Employee #1 apparently unscrewed the crossbar on the bottom of the cover all the way and it fell to the bottom of the tank. Rust and scale in the sealed compartment resulted in an oxygen deficient atmosphere, and when Employee #1 went down to retrieve the crossbar he died of asphyxia. Employee #2, who apparently went down to help Employee #1, also died of asphyxia. Employee #3, who was part of the rescue team, experienced chest pains and was kept at the hospital for observation for possible hyperventilation. There were no eyewitnesses to the accident.

Keywords: OXYGEN DEFICIENCY, BARGE, ASPHYXIATED, SHIPYARD, CONFINED SPACE, WORK RULES, INHALATION, SCBA, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101476737 Fatality Asphyxia Occupation not reported
2 101476737 Non Hospitalized injury Asphyxia Occupation not reported
3 101476737 Hospitalized injury Strain/Sprain Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.