Accident Summary Nr: 14392732 - Employee killed in 20 ft fall from single scaffold board

Accident Summary Nr: 14392732 -- Report ID: 0625700 -- Event Date: 11/15/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
30039227111/19/199626110Ark Ka Tex Auto Auction Inc.

Abstract: Employee #1, a supervisor, and a coworker were trying to clear a blockage in a pulp feed line in a paper mill. Employee #1 climbed out onto a single scaffold board that had been laid across a handrail and another pipe. When he opened an inspection plug in a pulp feed line to try to find the blockage, pressurized air shot out of the opening. The board broke in half and Employee #1 fell approximately 20 feet to the ground, landing on his shoulder and head. He was killed.

Keywords: BOARD, HEAD, MAINTENANCE, SHOULDER, WORK RULES, CLOGGED, FALL, MILL--PLANT, ACCIDENTAL DISCHARGE, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300392271 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.