Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14391353 - LONGSHOREMAN KILLED WHEN HE FELL INTO BARGE'S HOLD

Accident Summary Nr: 14391353 -- Report ID: 0625700 -- Event Date: 02/19/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10161916102/20/198844910Ceres Gulf, Inc.

Abstract: AT APPROXIMATELY 5:45 AM ON FEBRUARY 19, 1988, A LONGSHORING CREW WAS CLOSING THE HOLD COVERS (HATCHES) ON A BARGE. THE SHIP "RAVENNA"'S AFT #3 CRANE WAS BEING USED TO MOVE THE COVERS. DURING CLOSING, THE DOGS (LOCKING/HOLDING DEVICES) FAILED TO STAY LOCKED AND ALLOWED AN OPENING BETWEEN TWO (2) COVERS/HATCHES OF APPROXIMATELY SEVEN (7) FEET. EMPLOYEE #1 FELL ABOUT 10 FEET INTO THE BARGE AND ON TOP OF A STACK OF STEEL. HE WAS KILLED.

Keywords: LOADING, LONGSHORING, BARGE, COVER, UNGUARDED FL OPENING, UNSECURED, WORK RULES, FALL, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101619161 Fatality Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.