Accident Summary Nr: 14391312 - EMPLOYEE KILLED WHEN KNOCKED AGAINST GUARDRAIL BY LIFT LOAD

Accident Summary Nr: 14391312 -- Report ID: 0625700 -- Event Date: 01/17/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10082985201/20/198836240Lake Charles Carbon Co.

Abstract: AT APPROXIMATELY 3:30 PM ON JANUARY 17, 1988, EMPLOYEE #1, A FORKLIFT OPERATOR, WAS TRYING TO MOVE A PALLET FULL OF BUNDLED SKIDS. THE LOAD WEIGHED ABOUT 2,600 POUNDS. EMPLOYEE #1 WAS USING AN 8,000 POUND CAPACITY HYSTER FORKLIFT, SERIAL NUMBER C004DC3452Y. HE INTENDED TO PLACE THE PALLET ON A PALLET STAND IN THE BAKED ANODE STORAGE STRAPPING AREA. THE PALLET STAND WAS 37 INCHES OFF THE FLOOR AND HAD LOOSE SKIDS SITTING ON TOP OF IT. HE ATTEMPTED SEVERAL TIMES, UNSUCCESSFULLY, TO PLACE THE LOAD. THE MORE ATTEMPTS WERE MADE TO PLACE THE LOAD, THE MORE OFF CENTER THE LOAD SHIFTED. THE LOAD SHIFTED TO THE POINT OF ALMOST TIPPING OVER. ANOTHER FORKLIFT OPERATOR WHO HAD BEEN OBSERVING THE OPERATION ASKED EMPLOYEE #1 IF HE COULD ASSIST. EMPLOYEE #1 GOT OFF THE FORKLIFT AND TRIED TO BRACE THE LOAD WITH HIS HANDS OVER HIS SHOULDERS PUSHING AGAINST THE LOAD. THE ASSISTING OPERATOR MOVED THE CONTROLS OF THE FORKLIFT. AS SOON AS THE FORKS WERE RAISED, THE LOAD TIPPED OVER ONTO EMPLOYEE #1. HE FELL BACKWARD AND WAS KILLED WHEN HIS HEAD STRUCK AGAINST A GUARDRAIL.

Keywords: HEAD, WORK RULES, EQUIPMENT OPERATOR, LOAD SHIFT, INDUSTRIAL TRUCK, PALLET, STRUCK BY, FALLING OBJECT, UNSTABLE LOAD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100829852 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close