Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14388151 - ELECTRIC SHOCK - ELECTRICAL FAULT IN INDUCTION FURNACE

Accident Summary Nr: 14388151 -- Report ID: 0524700 -- Event Date: 06/05/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
235549306/05/198933210Alloy Founders Inc.

Abstract: AN EMPLOYEE WAS ASSISTING A FURNACE OPERATOR IN LOADING LARGE PIECES OF SCRAP METAL INTO AN ELECTRIC CORELESS INDUCTION FURNACE. (THIS PROCESS IS KNOWN AS CHARGING THE FURNACE.) THE MOLTEN METAL WITHIN THE FURNACE HAD BECOME ENERGIZED APPARENTLY DUE TO A FAULT TO THE INDUCTION COIL. THE GROUNDING PRONGS, WHICH SHOULD HAVE CAUSED THE FURNACE TO SHUT DOWN, HAD NOT BEEN REINSTALLED WHEN THE FURNACE WAS RECENTLY RELINED. THE EMPLOYEE WAS ELECTROCUTED WHEN HE PLACED A PIECE OF SCRAP INTO THE ENERGIZED MOLTEN METAL INSIDE THE FURNACE.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, SCRAP METAL, ELECTRICAL FAULT, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2355493 Fatality Electric Shock Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.