Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14388052 - Employee without ppe dies of carbon monoxide poisoning

Accident Summary Nr: 14388052 -- Report ID: 0524700 -- Event Date: 03/03/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10306082803/07/198932950Stein, Inc.

Abstract: Employee #1 was operating a Crackall, model 660, truck crane to unplug a cone-shaped dust bin by inserting a 136 in. long by 3 in. diameter metal finger into the valve opening in the bottom of the dust bin. He was overcome by carbon monoxide and died. His carboxyhemoglobin level was found to be 72 percent. Employee #1 was not provided with ppe and he had not received any information or training on carbon monoxide, as required by 1910.1200.

Keywords: OXYGEN DEFICIENCY, PPE, TRUCK CRANE, WORK RULES, EQUIPMENT OPERATOR, CARBOXYHEMOGLOBIN, POISONING, TOXIC FUMES, UNTRAINED, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103060828 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.