Accident Summary Nr: 14387385 - Foreman killed in trench cave-in

Accident Summary Nr: 14387385 -- Report ID: 0524200 -- Event Date: 02/26/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10112796702/26/198616230Carl Ward (Subsurface) Contractors, Inc.

Abstract: Employee #1, a foreman for an underground construction contractor, entered an approximately 18 ft deep by 20 ft long by 5 to 6 ft wide trench to line up an 8 in. diameter cast iron sewer pipe. He instructed a coworker to watch from the top for any movement in the excavation's unshored, near-vertical walls. The trench caved in and Employee #1 was crushed and killed. A trench box was available at the job site but was not in use. A citation was issued for willful violation of 29CFR 1926.20(b)(1), 20(b)(2) and 21(b)(2) and 29CFR 1926.65(i)(1) and 652(c), serious.

Keywords: TRENCH BOX, WORK RULES, CONSTRUCTION, TRENCH, CRUSHED, SHORING, SLOPING, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101127967 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close