Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14387039 - INHALATION OF VAPORS IN A CONFINED SPACE

Accident Summary Nr: 14387039 -- Report ID: 0524200 -- Event Date: 10/07/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
133070310/09/198436250Gpe Controls

Abstract: EMPLOYEE #1 WAS ASSIGNED TO DRAIN AND CLEAN A BARON BLAKESLEE DEGREASER. THE DEGREASER WAS SURROUNDED BY A 3-1/2 FOOT DEEP PIT, WHICH THE EMPLOYEE ENTERED TO OPEN THE VALUE AND DRAIN THE CONTENTS (METHYLENE CHLORIDE). THE EMPLOYEE WORE A DUST MUSK IN THE PIT. NO VENTILATING WAS DONE BEFORE ENTERING. NO MEASUREMENTS WERE TAKEN TO DETERMINE AIR CONTAMINANT LEVELS. NO OTHER PERSONNEL WERE PRESENT. THE EMPLOYEE WAS NOT TRAINED. THE EMPLOYEE WAS FOUND 1 HOUR LATER BY THE SUPERVISOR. HE WAS PRONOUNCED DEAD 2 HOURS LATER.

Keywords: MAINTENANCE, VENTILATION, CONFINED SPACE, METHYLENE CHLORIDE, DEGREASER, AIR CONTAMINATION, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1330703 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.