Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14385934 - One killed, two nearly overcome by gas in truck tank

Accident Summary Nr: 14385934 -- Report ID: 0521700 -- Event Date: 04/04/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10015357604/04/198676990B. J. Transportatin Service, Inc.

Abstract: Employee #1 entered a semi tanker trailer to wash out the inside, which had contained a fatty acid (linseed oil). A short time later, he was found lying at the bottom under the hatch opening. Employees #2 and #3 jumped in to rescue him and were nearly overcome. Employee #1 died, and blood tests conducted two hours after exposure revealed carboxyhemoglobin levels of 56 percent for Employee #1, and 15 and 25 percent for Employees #2 and #3, respectively. The vessel's atmosphere was later found to be an inert gas containing mostly nitrogen and about 5 percent carbon monoxide. The gas had been made by the plant that unloaded the trailer, and had been used to blow off the load. When the driver arrived at the truck washing facility, he had not informed the workers about the inert gas, nor had the manifest indicated its use. The tank washing facility had not tested the atmosphere in the tank before Employee #1 entered, and there was no confined space entry program in effect.

Keywords: OXYGEN DEFICIENCY, CONFINED SPACE, WORK RULES, INHALATION, NITROGEN, CARBOXYHEMOGLOBIN, POISONING, CARBON MONOXIDE, COMMUNICATION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100153576 Non Hospitalized injury Poisoning(Systemic) Occupation not reported
2 100153576 Fatality Poisoning(Systemic) Occupation not reported
3 100153576 Non Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.