Accident Report Detail
Accident Summary Nr: 14385298 - FELL 18 FEET FROM EXTENSION LADDER
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 2282390 | 08/19/1985 | 4899 | 0 | Cablevision Of Chicago |
Abstract: EMPLOYEE #1 WAS INSTALLING A CABLE TELEVISION LINE TO A RESIDENCE. HE WAS WORKING FROM AN EXTENSION LADDER, 18 FEET ABOVE THE GROUND. HE WAS INSTALLING A "DRIP LOOP" ON THE CABLE. HIS CO-WORKER WAS AT GROUND LEVEL, INSTRUCTING HIM HOW TO INSTALL THE LOOP. EMPLOYEE #1 DROPPED A CRESCENT WRENCH. EMPLOYEE #2 BENT TO PICK IT UP. WHEN HE LOOKED UP EMPLOYEE #1 WAS FALLING FROM THE LADDER. THE CO-WORKER SPECULATES THAT THE "MESSENGER" (PART OF THE CABLE) BROKE, CAUSING THE CABLE TO PULL THE SPAN CLAMP. EITHER THIS CAUSED EMPLOYEE #1 TO LOSE HIS BALANCE OR THE CABLE MOVEMENT CAUSED THE LADDER TO MOVE. EMPLOYEE #1 WAS TAKEN TO THE HOSPITAL, UNCONSCIOUS. HE DIED FOUR DAYS LATER.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 2282390 | Fatality | Concussion | Occupation not reported |
Translate