Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14383475 - Employees suffer overexposure from carbon monoxide

Accident Summary Nr: 14383475 -- Report ID: 0524530 -- Event Date: 01/11/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10655736601/12/199342250Lanter Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10655737401/12/199342250Sears Logistics Services
Inspection NrDate OpenedSICNAICSEstablishment Name
10655736601/12/199342250Lanter Company

Abstract: Employees #1 through #19 were overcome by carbon monoxide from approximately 20 lpg-powered industrial trucks operating inside a warehouse. There was no mechanical exhaust ventilation in the warehouse. Employees #5, #7, #10, and #14 through #19 remained hospitalized overnight.

Keywords: VENTILATION, WAREHOUSE, WORK RULES, INHALATION, INDUSTRIAL TRUCK, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 106557366 Non Hospitalized injury Asphyxia Occupation not reported
2 106557366 Non Hospitalized injury Asphyxia Occupation not reported
3 106557366 Hospitalized injury Asphyxia Occupation not reported
4 106557366 Non Hospitalized injury Asphyxia Occupation not reported
5 106557366 Non Hospitalized injury Asphyxia Occupation not reported
6 106557366 Non Hospitalized injury Asphyxia Occupation not reported
7 106557366 Hospitalized injury Asphyxia Occupation not reported
8 106557366 Hospitalized injury Asphyxia Occupation not reported
9 106557366 Hospitalized injury Asphyxia Occupation not reported
10 106557366 Hospitalized injury Asphyxia Occupation not reported
11 106557366 Hospitalized injury Asphyxia Occupation not reported
12 106557366 Hospitalized injury Asphyxia Occupation not reported
13 106557366 Hospitalized injury Asphyxia Occupation not reported
14 106557366 Hospitalized injury Asphyxia Occupation not reported
15 106557366 Non Hospitalized injury Asphyxia Occupation not reported
16 106557374 Non Hospitalized injury Asphyxia Occupation not reported
17 106557374 Non Hospitalized injury Asphyxia Occupation not reported
18 106557374 Non Hospitalized injury Asphyxia Occupation not reported
19 106557366 Non Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.