Accident Summary Nr: 14382402 - Employee injured in fall through roof opening

Accident Summary Nr: 14382402 -- Report ID: 0521700 -- Event Date: 10/01/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
248362610/04/198517110R J O'Sullivan
Inspection NrDate OpenedSICNAICSEstablishment Name
248363410/04/198515420Wil-Freds Construction/Midwest
Inspection NrDate OpenedSICNAICSEstablishment Name
10102570810/17/198517110Air Crafters Ventilation Inc
Inspection NrDate OpenedSICNAICSEstablishment Name
10102594810/17/198517940L&J Reimer Excavating
Inspection NrDate OpenedSICNAICSEstablishment Name
10102569010/17/198517310Service Electric Co
Inspection NrDate OpenedSICNAICSEstablishment Name
10102546810/17/198517420R G Interiors
Inspection NrDate OpenedSICNAICSEstablishment Name
10102595510/17/198517610Crown Core Limited

Abstract: At 2:30 p.m. on October 1, 1985, Employee #1, a plumber, was working alone on the flat roof of a 2-story building, packing the joint on a roof drain. He apparently lifted the cover on a roof opening to talk to a coworker who was working on the floor below him. The coworker had his back to the opening. Employee #1 fell onto the plywood floor opening cover on the second floor. This cover failed and Employee #1 and the cover fell to the first floor. Employee #1 required hospitalization. The covers were made of 5/8 in. plywood, were marked "do not remove," and were cleated to prevent accidental displacement.

Keywords: FALL, FALL PROTECTION, FLOOR OPENING, ROOF OPENING COVER, WORK RULES, ROOF OPENING, CONSTRUCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2483626 Hospitalized injury Fracture Occupation not reported
2 2483634 Occupation Not Listed
3 101025708 Occupation Not Listed
4 101025948 Occupation Not Listed
5 101025690 Occupation Not Listed
6 101025468 Occupation Not Listed
7 101025955 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.