Accident Summary Nr: 14382170 - EMPLOYEES ALLEGEDLY EXPOSED TO CYANIDE

Accident Summary Nr: 14382170 -- Report ID: 0521400 -- Event Date: 05/08/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
222735305/09/198534710Access Plating Industries Inc

Abstract: ON MAY 8, 1985, EMPLOYEES #1-5 WERE TAKEN TO THE HOSPITAL, TREATED FOR AN ALLEGED EXPOSURE TO CYANIDE, AND RELEASED. ALL FIVE EMPLOYEES WORK FOR AN ELECTROPLATING FIRM. THE INCIDENT OCCURRED WHEN AN EMPLOYEE WHO WAS MIXING CHEMICALS ADDED ONE GALLON OF HYDROCHLORIC ACID TO A TANK CONTAINING SULFURIC AND NITRIC ACIDS. LARGE AMOUNTS OF VAPOR WERE GENERATED IN THIS ACID TANK. THE CYANIDE TANK WAS LOCATED NEARBY.

Keywords: VAPOR, HYDROGEN CHLORIDE, CHEMICAL REACTION, NITRIC ACID, CHEMICAL VAPOR, SULFURIC ACID, TANK, CYANIDE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2227353 Hospitalized injury Asphyxia Chemical engineers
2 2227353 Hospitalized injury Asphyxia Chemical engineers
3 2227353 Hospitalized injury Asphyxia Laborers, except construction
4 2227353 Hospitalized injury Asphyxia Laborers, except construction
5 2227353 Hospitalized injury Asphyxia Chemical engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.