Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 143775.015 - Employee partially amputates finger on table saw

Accident Summary Nr: 143775.015 -- Report ID: 0454715 -- Event Date: 01/26/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1577827.01502/11/2022337127Institutional Casework, Incorporated

Abstract: At 12:45 p.m. on January 26, 2022, an employee was removing dowels that were jammed in between a saw blade and the saw body when the push stick he was using got caught in the slow moving saw blade and pulled his hand in. The employee had shut the power off to the saw prior to attempting to remove the dowels but the blade was still spinning. The employee was hospitalized to treat a partial amputation of his left pinky finger.

Keywords: Amputated, Amputation, Blade, Caught By, Cutting, Finger, Fingertip, Hand, Jammed, Partial Amputation, Pulled In, Push Stick, Table Saw

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1577827.015 38 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.