Accident Summary Nr: 14377014 - AMPUTATION OF FINGER IN CHAIN AND SPROCKET

Accident Summary Nr: 14377014 -- Report ID: 0521700 -- Event Date: 05/30/1984
Inspection NrDate OpenedSICNAICSEstablishment Name
133782306/29/198434790Chicago Steel & Pickling Co

Abstract: ON MAY 30, 1984, EMPLOYEE #1 WAS REACHING FOR SOME METAL STRAP USED TO BAND CUT STEEL SHEETS TOGETHER PRIOR TO SHIPPING. HE WAS WEARING GLOVES. HE WAS IN THE PROCESS OF REACHING AROUND THE LOWER PART OF THE STACK OF PLATES WHEN THE ROLLERS, POWERED BY GANGED CHAINS AND SPROCKETS, STARTED UP WITHOUT WARNING. HIS GLOVE APPARENTLY GOT CAUGHT IN THE IN-RUNNING NIP POINT OF THE CHAIN AND SPROCKET DRIVE, LOCATED ON THE NORTH SIDE OF THE CONVEYOR, WHERE GUARDING WAS EITHER INCOMPLETE OR REMOVED. HIS HAND WAS DRAWN INTO THE MACHINERY, AMPUTATING HALF OF ONE OF HIS FINGERS. HE WAS TAKEN TO THE CHICAGO SOUTH HOSPITAL EMERGENCY WARD. NO FIRST AID WAS GIVEN TO THE EMPLOYEE PRIOR TO ARRIVAL AT THE HOSPITAL.

Keywords: CHAIN, AMPUTATED, PPE, FINGER, GUARD, LOCKOUT, CONVEYOR, POWER TRANS APPAR, SPROCKET, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1337823 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close