Accident Summary Nr: 143764.015 - Employee's fingers are amputated in mechanical power press

Accident Summary Nr: 143764.015 -- Report ID: 0521100 -- Event Date: 02/08/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1578481.01502/15/2022336370Jagemann Stamping Company

Abstract: At 7:00 a.m. on February 8, 2022, a 27-year-old employee was working as a machine operator for a firm that made metal stampings for motor vehicles. She was operating the firm's E.W. Bliss C45 45-ton (440-kilonewton) part-revolution mechanical power press. The press was set to a single-stroke setting, with the operator performing hand-in-die loading. The press was operated by controls on a movable control station. A yellow flexible cord connected the station to the press. The press was set to actuate when the two hand controls on the movable control station were depressed. The station had been positioned at the front of the press. It was raised up on a wooden block that measured 3.375 inches (86 mm) by 2.625 inches (67 mm) in thickness. This permitted the operator to place the parts tray near the front of the die area. The press was set up to run small parts that were 1.5 inches (38 mm) long and in the shape of a dog bone. The die stamped a chamfered edge on two parts per cycle. At times, the parts would not sit correctly in the die spaces, and the operator would need to reposition them to ensure that they were stamped correctly. The operator had run 6,000 to 7,000 parts through the press on the work shift and had coiled up oil rags to pad the control buttons cusps. As the employee was reaching into the die area to reposition the parts in the die, her body came into contact with the control buttons. The press actuated unexpectedly. The employee suffered amputation injuries one or more fingers. One account said that the middle finger on her left hand was partially amputated. Another account said that the amputations were to or of the middle and index fingers on her right hand. She was treated without hospitalization.

Keywords: Amputated, Amputation, Caught In, Die, Finger, Hand, Hand Control, Leaning over, Machine Cycled, Machine operator, Mechanical Power Press, Partial Amputation, Point Of Operation, Training, Work Rules

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1578481.015 27 F Non Hospitalized injury Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close