Accident Summary Nr: 14372429 - EMPLOYEES BURNED BY FLY ASH

Accident Summary Nr: 14372429 -- Report ID: 0523300 -- Event Date: 06/08/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12246153606/08/199449310Wisconsin Power And Light Co.

Abstract: A supervisor and another employee were unplugging a line containing fly ash. They were standing on top of a tank used to collect the fly ash from three hoppers located above them. When the clog suddenly let go, the economizer tank could not handle the sudden flow of fly ash, and an unsecured tank cover and the water gasket blew out. The employees were showered with hot fly ash from the hoppers. Both employees were burned, and one of them was hospitalized for his injuries. The employees had not closed the valves leading from the hoppers, had no job briefing, and were not wearing appropriate personal protective equipment. Additionally, the employer did not have a documented procedure for performing the unplugging, though it was a common occurrence.

Keywords: BURN, COVER, PPE, CLOGGED, VALVE, ELEC UTILITY WORK, STRUCK BY, TANK, ACCIDENTAL DISCHARGE, HOPPER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122461536 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 122461536 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close