Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14371215 - Employee injured when caught in hydraulic press

Accident Summary Nr: 14371215 -- Report ID: 0522000 -- Event Date: 06/22/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10303271006/22/199234690Pentaflex, Inc.

Abstract: Employee #1 got his arm caught in the point of operation of a hydraulic press after the supervisor turned off one set of the hand controls. Then a coworker pressed and held down his controls, catching Employee #1 in the point of operation.

Keywords: HAND CONTROL, CAUGHT BY, POINT OF OPERATION, ARM, HYDRAULIC PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103032710 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close