Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14367650 - Employee dies after becoming entangled in lathe

Accident Summary Nr: 14367650 -- Report ID: 0523400 -- Event Date: 03/29/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
12204463903/29/199535990Waller Machine, Inc.

Abstract: Employee #1, considered to be a qualified machinist, had worked for the firm since June 10, 1991, and was the operator of the #5 Bullard vertical (boring mill) lathe. At 2:10 p.m. on March 29, 1995, he was machining the inside diameter of a steel ring (track) that was secured to a rotating table that turned at approximately 25 to 27 rpm. A stationary tool holder was positioned at the right side of the table, adjacent to the machine housing. Employee #1 was wearing rubber-coated gloves and a long-sleeve shirt or garment at the time of the accident, to which there were no witnesses. A coworker working on the lathe to the left of Employee #1 heard an abrasive sound, turned to his right, and saw that Employee #1 was caught in the machine; he ran to help. As a result of coming in contact with the turntable and the hold-down clamps -- that are spaced at 30-inch intervals around the table's periphery and protrude up 2 inches from the top of the rim -- Employee #1 sustained a deep laceration on his right wrist to the point of severance and a deep laceration in the middle of his back. Serious bleeding and cardiac arrest ensued. Employee #1 died at the scene. The front of the lathe had a partial solid shield awareness barrier that extended 36 inches up from the floor, leaving the entire right half of the periphery, 98 3/4 inches, exposed to unshielded contact. The missing two sections of the shield, equipped with hinged pin connections, were found stored in the immediate area. There was no explanation why these sections were not in place. ANSI Standard B11.6-1984, Sections 5.7 and 7.1.7, specifies that an awareness barrier that extends at least 42 inches above the floor shall be provided and shall be in place while the lathe is being operated. It has not been determined what Employee #1's job function was at the time of the accident. The employer stated that he has provided information to the employees on safety rules.

Keywords: LATHE, LOSS OF BLOOD, MACHINIST, WORK RULES, BACK, CARDIAC ARREST, LACERATION, ENTANGLED, UNGUARDED, WRIST

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122044639 Fatality Cut/Laceration Machinists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.