Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14367072 - Employees overexposed to carbon monoxide

Accident Summary Nr: 14367072 -- Report ID: 0523400 -- Event Date: 02/24/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12203301202/26/199317610J.T. Roofing, Inc.

Abstract: Employees #1, #2, #3, #4, and #5 were inside a 34 ft wide, 49 ft long, and 14 ft high warehouse, removing 450 sq ft of 6 in. concrete. They were using a Gehl Model SL 4510 gas-powered skid steer loader, an Oliver Corp., White-Olive Model 1678 gas-powered back-hoe, and an Oliver Corp. model 1650 gas-powered hydraulic jackhammer. Due to the cold weather, the two overhead doors were kept closed except to let the skid steer loader in and out. After three or four hours in this area Employees #1 through #5 had symptoms of carbon monoxide poisoning such as headache, nausea, dizziness, and stumbling. Their blood gas readings ranged from 17 percent to 35 percent carboxyhemoglobin. All five were treated with oxygen at a local hospital; two were sent to another hospital for oxygen treatment in a hyperbaric chamber. All were released from treatment that same day.

Keywords: VENTILATION, WAREHOUSE, CONSTRUCTION, INHALATION, NAUSEA, DIZZINESS, EXHAUST FUMES, CARBOXYHEMOGLOBIN, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122033012 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 122033012 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 122033012 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 122033012 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 122033012 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.