Accident Summary Nr: 14366991 - Iron worker injured in fall from ladder

Accident Summary Nr: 14366991 -- Report ID: 0523400 -- Event Date: 01/28/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12203327701/28/199317910Price Erecting, Inc.

Abstract: Employee #1 an iron worker, was working from a 10 ft straight fiberglass ladder using a come-along to position a steel diagonal brace for welding. The ladder was equipped with nonslip bases and was placed on a 2 ft by 3 ft piece of plywood that was resting on snow- and ice-covered concrete. The ladder slipped out and the employee fell 9 ft to an open-sided floor at the edge of a balcony. Employee #1 then fell an additional 12 ft to a precast concrete deck, fracturing his hip, elbow, and arms. The top of the ladder was resting against a horizontal beam, where a tie wire was present with an intact completed loop with the ends twisted closed. There was no indication that the ladder was effectively lashed or blocked to prevent it from slipping.

Keywords: FRACTURE, UNSECURED, IRON WORKER, WORK RULES, LADDER, FALL, SLIPPERY SURFACE, ELBOW, HIP, OPEN-SIDED FLOOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122033277 Hospitalized injury Fracture Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close