Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14360911 - Employees are overcome by fumes in manhole

Accident Summary Nr: 14360911 -- Report ID: 0521700 -- Event Date: 01/26/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10872011101/26/199450930Midwest Metallics, L.P.

Abstract: Employees #1 and #2 entered a manhole to attempt repairs and died. Employee #3 attempted to rescue Employee #2 and was overcome by the hydrogen sulfide fumes. Employee #4 was overcome by fumes while attempting to rescue Employee #3. Employee #5 was overcome by fumes while attempting to rescue Employee #4. Employees #4 and #5 exited the manhole. The local fire department rescued Employee #3. Employee #6 became ill while outside the manhole.

Keywords: REPAIR, CONFINED SPACE, PPE, HYDROGEN SULFIDE, VENTING, WORK RULES, TOXIC FUMES, MANHOLE, OVEREXPOSURE, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108720111 Fatality Asphyxia Occupation not reported
2 108720111 Fatality Asphyxia Occupation not reported
3 108720111 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 108720111 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 108720111 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 108720111 Hospitalized injury Poisoning(Systemic) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.