Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14352686 - EMPLOYEES DIED OF OXYGEN DEFICIENCY IN OIL RIG BALLAST TUBE

Accident Summary Nr: 14352686 -- Report ID: 0418600 -- Event Date: 12/10/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
197018512/10/198513110Ocean Drilling And Exploration Co.

Abstract: THREE MEN WERE INSPECTING THE INTERIOR OF A BALLAST TUBE ON A SEMISUBMERSIBLE OIL DRILLING RIG. THE RIG HAD BEEN DRYDOCKED AT A SHIPYARD FOR REPAIRS. THE BALLAST TUBE WAS HOLLOW AND ABOUT 108 FEET LONG. THE INSIDE DIAMETER WAS 10 FEET. THE TUBE WAS DIVIDED VERTICALLY INTO THREE COMPARTMENTS. THE MEN TESTED THE AIR IN THE ACCESS COLUMN AND DESCENDED A 24 FOOT FIXED LADDER TO THE BOTTOM OF THE FIRST COMPARTMENT. THEY THEN REMOVED THE MANHOLE COVER FROM THE TOP OF THE SECOND COMPARTMENT AND TESTED THE AIR THERE. IT WAS FOUND TO BE SAFE, SO EMPLOYEE #2 ENTERED THE COMPARTMENT AND STARTED DOWN THE LADDER. AFTER HE HAD GONE ABOUT FIVE FEET DOWN THE LADDER HE FELL THE REMAINING 32 FEET TO THE BOTTOM OF THE COMPARTMENT. THE THIRD EMPLOYEE THEN LEFT THE TUBE TO LOOK FOR HELP IN RESCUING THE EMPLOYEE WHO FELL. BY THE TIME HE RETURNED WITH HELP, THE OXYGEN ALARM WAS OPERATING AND BOTH OF THE OTHER EMPLOYEES WERE FOUND LYING AT THE BOTTOM OF THE SECOND COMPARTMENT. AUTOPSY REPORTS SHOWED THAT BOTH MEN DIED OF ASPHYXIA AND BLUNT FORCE INJURIES.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, AIR MONITORING, FALL, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1970185 Fatality Asphyxia Engineers, n.e.c.
2 1970185 Fatality Asphyxia Marine engineers and naval architects

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.