Accident Summary Nr: 14347967 - ELECTRIC SHOCK - GROUND FAULT IN CONVEYOR

Accident Summary Nr: 14347967 -- Report ID: 0418300 -- Event Date: 07/20/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10599176407/22/198824210Frost Lumber Co., Inc.

Abstract: AN EMPLOYEE WAS SHUTTING DOWN A VIBRATING CONVEYOR THAT TOOK SCRAP LUMBER TO A CHIPPER. THE EMPLOYEE WAS NEAR THE VIBRATING CONVEYOR AND THE DECK OF A TRIM-SAW CONVEYOR. A SLAB CAME OUT OF THE VIBRATING CONVEYOR AND WAS PUSHED OR FELL AGAINST THE WIRING TO A CONTROL BOX FOR THE CONVEYOR. THE SLAB PULLED THE WIRING FROM THE BOX, AND THE CONDUCTORS FOR THE 480-VOLT CIRCUIT FELL ONTO THE CONVEYOR, ENERGIZING IT. THE EMPLOYEE STARTED TO GO ACROSS THE CONVEYOR, BUT WAS ELECTROCUTED UPON CONTACT WITH IT.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, CONVEYOR, EQUIPMENT GROUNDING, ELECTRIC CONDUCTOR, ELECTRICAL BOX, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105991764 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.