Accident Summary Nr: 14347959 - One employee killed, one injured in platform collapse

Accident Summary Nr: 14347959 -- Report ID: 0418300 -- Event Date: 05/10/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10599108705/11/198833120Koppers Industries, Woodward Coke Plant

Abstract: At approximately 9:45 a.m. on May 10, 1988, Employees #1 and #2 were preparing to remove the drive pulleys from a fresh air blower that was mounted on a structural steel platform 14 ft above a wharf coke pit. The steel beams, which had deteriorated, collapsed. Employee #1 suffered blunt force trauma to the chest and was pronounced dead at the scene. Employee #2 suffered a contusion and laceration to the scalp, forehead, and nose and was hospitalized.

Keywords: BEAM, CHEST, STEEL BEAM, COLLAPSE, INADEQUATE MAINT, EQUIPMENT FAILURE, LACERATION, STRUCK BY, FALLING OBJECT, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105991087 Fatality Bruise/Contus/Abras Occupation not reported
2 105991087 Hospitalized injury Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close