Accident Summary Nr: 14347363 - Five employees injured when struck by collapsing roof

Accident Summary Nr: 14347363 -- Report ID: 0418400 -- Event Date: 12/26/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10035791212/29/198617510David Howard Construction Company

Abstract: Employees #1 through #5 were working on a 2-story frame office building. Employee #1 was working on a second floor wall; Employee #2 was standing on a sawhorse furring out a wall; Employees #3 and #4 were standing on the trusses over a beam; and Employee #5 was supervising the framing. A loud crack and then shouted warnings were heard. The beam broke and the partially completed roof collapsed. Employees #1, #2, #4, and #5 were bruised and Employee #3 sustained fractures; all five employees were treated at a local hospital. The roof trusses had not been adequately braced during construction, causing the 4 by 6 treated timber roof support beam that was being used as the center interior bearing to fail under truss "A." In addition to the inadequate design of the beam, several bundles of 4 by 8 ft plywood sheets weighing 3,000 lb had been lying on the wood roof for four to seven days. Bracing/blocks were being installed on the trusses. Spreading bundles on the roof was a common construction practice.

Keywords: FRACTURE, ROOF, COLLAPSE, WORK RULES, OVERLOADED, CONSTRUCTION, STRUCK BY, BRACING, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100357912 Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 100357912 Hospitalized injury Bruise/Contus/Abras Occupation not reported
3 100357912 Hospitalized injury Bruise/Contus/Abras Occupation not reported
4 100357912 Hospitalized injury Bruise/Contus/Abras Occupation not reported
5 100357912 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.