Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14346431 - HEAD CRUSHED UNDER FALLING PIECE OF HYDRAULIC EQUIPMENT

Accident Summary Nr: 14346431 -- Report ID: 0420600 -- Event Date: 11/20/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
230758511/20/198516110Briar Construction & Paving Company, Inc.

Abstract: EMPLOYEE #1 WAS PREPARING TO SERVICE A PB GRADER, MODEL PB510 BWE, SERIAL NUMBER PBG 82K330, WHEN HE OBSERVED A LEAKING HYDRAULIC FITTING ON A CYLINDER USED TO RAISE AND LOWER A PLATE COMPACTOR/RIPPER ATTACHMENT ON THE REAR OF THE MACHINE. THE ATTACHMENT WAS IN THE RAISED POSITON WHEN EMPLOYEE #1 CRAWLED UNDER THE MACHINE TO TIGHTEN THE FITTING. HE DID NOT BLOCK THE ATTACHMENT UP OR LOWER IT TO THE GROUND BEFORE ATTEMPTING THE REPAIR. EMPLOYEE #1 APPARENTLY OVERTIGHTENED THE FITTING. IT BROKE OFF, ALLOWING THE ATTACHMENT TO FALL TO THE GROUND. A PART OF THE ATTACHMENT STRUCK THE EMPLOYEE IN THE HEAD, INFLICTING SEVERE HEAD INJURIES. THE EMPLOYEE DIED THE FOLLOWING DAY.

Keywords: HEAD, REPAIR, BLOCKS, HYDRAULIC FLUID, CONSTRUCTION, HYDRAULIC CYLINDER, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2307585 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.