Accident Summary Nr: 143463.015 - Employee fractures arm when pulled into machine clearing jam

Accident Summary Nr: 143463.015 -- Report ID: 0419400 -- Event Date: 01/28/2022
Inspection NrDate OpenedSICNAICSEstablishment Name
1576236.01502/03/2022321219Masonite Corporation

Abstract: At 12:30 a.m. on January 28, 2022, an employee was loading fiberboard panels onto conveyor belt. The employee stopped loading and attempted to clear a jam at the machine end of the conveyor when his right jacket sleeve was caught by the machine. The employee hit the E-Stop and was able to free himself from the machine. Lockout/Tagout was not being utilized. The employee incurred multiple fractures to his arm, requiring hospitalization.

Keywords: Arm, Blunt force, Blunt force trauma, Board, Catch Point, Caught In, Conveyor, Emergency Stop, Engineering Controls, Fracture, Lack of Engineering Controls, Loading, Lockout, Lockout/Tagout, Machine operator, Pinched, Pulled In

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1576236.015 30 M Hospitalized injury

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.