Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14336432 - EMPLOYEE KILLED IN A FALL FROM COMMUNICATION TOWER

Accident Summary Nr: 14336432 -- Report ID: 0418100 -- Event Date: 12/16/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
1834460612/19/198917990Casey Tower Service, Inc.

Abstract: At 1:00 p.m. on December 16,1989, Employee #1 went to the top of a self-supporting Rohn 285-ft Communications tower (being built for a cellular telephone company) in order to make a template of the top tower flange for the beacon plate. He had on a safety belt and a lanyard. After 20 minutes or so, coworkers below heard a scream, and Employee #1 fell from the top of the tower to the ground. He died on impact. He was found with the completed template stuck in his coveralls. The small rope snap of the safety lanyard was not connected. Other employees speculated that the small rope snap rolled out of the safety belt D ring. Company should establish a safety program which provides specific job site safety rules. For example, establish a training program to cover job site safety rules, provide locking rope snaps for the safety belt and lanyard, proof test shop-made spreader snaps, and prohibit riding the hoist block to the top of the tower.

Keywords: SAFETY BELT, LANYARD, FALL, TOWER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18344606 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close