Accident Report Detail
Accident Summary Nr: 143345.015 - Six employees incur respiratory illnesses caused by vapor re
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1575962.015 | 02/02/2022 | 312120 | Blues City Brewery, Llc |
Abstract: At 10:10 a.m. on February 1, 2022, an employee connected the wrong chemical tote, i.e. Dilac instead of Dibac, to a day tank containing a chlorine solution. The chemical reaction of the two chemicals caused a vapor release into the Government Cellar area. Eight employees sustained unspecified respiratory illnesses, six of the employees were hospitalized for treatment.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury |
|---|---|---|---|---|---|
| 1 | 1575962.015 | 33 | M | Non Hospitalized injury | |
| 2 | 1575962.015 | 44 | M | Hospitalized injury | |
| 3 | 1575962.015 | 56 | M | Non Hospitalized injury | |
| 4 | 1575962.015 | 38 | M | Hospitalized injury | |
| 5 | 1575962.015 | 50 | F | Hospitalized injury | |
| 6 | 1575962.015 | 51 | M | Hospitalized injury | |
| 7 | 1575962.015 | 53 | F | Hospitalized injury | |
| 8 | 1575962.015 | 36 | F | Hospitalized injury |
Translate