Accident Summary Nr: 14333975 - Employee dies when crushed between molding machine parts

Accident Summary Nr: 14333975 -- Report ID: 0420600 -- Event Date: 04/17/1995
Inspection NrDate OpenedSICNAICSEstablishment Name
10920125104/18/199530890Proto Corporation

Abstract: On April 17, 1995, a vacuum molding machine was malfunctioning and the employees were repairing it. The machine's timer was set to automatically turn the carousel every 45 seconds. Employee #1 was inside the carousel; he would listen for an air flow noise, which indicated that the carousel would be turning, and duck. He stood once the turn was completed. During one turn, he ducked, but then stood up before the cycle began. He was crushed between the oven and the carousel frame and died.

Keywords: ROTATING PARTS, REPAIR, MOLDING MACHINE, WORK RULES, CRUSHED, PLASTIC MFG, MACHINE--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109201251 Fatality Other Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.