Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14332829 - OVERTURNED CRANE FELL BACK ONTO OPERATOR, WHO HAD JUMPED OUT

Accident Summary Nr: 14332829 -- Report ID: 0418100 -- Event Date: 06/17/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10033990206/17/198673590Superior Rigging & Erecting Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10033989406/17/198616230J. E. Lovern Construction Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10033988606/17/198615420Hairston Construction Co. Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10033991006/26/198632720Cobb County Concrete Products, Inc.

Abstract: A 20 TON HYDRAULIC TRUCK CRANE WAS SENT BY CRANE RENTAL SERVICE TO HANDLE THE TASK OF MOVING A 26,000 POUND REINFORCED CONCRETE HOLDING TANK. THE FINAL PART OF THE JOB WAS THE LOWERING OF THE TANK INTO A 20 FOOT DEEP EXCAVATION. THE CRANE WAS POSITIONED AS CLOSE TO THE EXCAVATION AS POSSIBLE, WITH 4 BY 4 TIMBERS PLACED UNDER THE OUTRIGGERS TO SPREAD THE LOADING AS MUCH AS POSSIBLE. THE TANK WAS POSITIONED OVER THE EXCAVATION AND LOWERED ABOUT HALF THE WAY TO THE BOTTOM. THE SIGNALMEN INDICATED TO THE CRANE OPERATOR THAT THE LOAD HAD TO BE EXTENDED ABOUT ANOTHER FOOT TO CLEAR THE SIDEWALL. AS THE OPERATOR (EMPLOYEE #1) EXTENDED THE BOOM, THE CRANE SUDDENLY FLIPPED OVER BACKWARDS. EMPLOYEE #1 JUMPED FROM THE CRANE CAB, BUT WAS UNABLE TO AVOID THE CRANE AS IT FELL BACK TO THE GROUND. HE WAS STRUCK AND CRUSHED TO DEATH BY THE FALLING CRANE.

Keywords: TRUCK CRANE, STRUCK BY, OVERTURN, CRUSHED, FALLING OBJECT, CRANE, UNSTABLE POSITION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100339902 Fatality Other Crane and tower operators
2 100339894 Occupation Not Listed
3 100339886 Occupation Not Listed
4 100339910 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close