Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14330393 - Employee killed when he asphyxiates in manhole

Accident Summary Nr: 14330393 -- Report ID: 0317700 -- Event Date: 08/12/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
62445212/19/198817110Dura Bond Corporation

Abstract: On August 12, 1987, Employee #1 entered a 25 ft deep by 4 ft diameter manhole alone to make preliminary plans for connecting a drain pipe to a sewer line. He was found dead the next day. Employee #1 had either died of asphyxiation from oxygen deficiency or been suffocated by the pressure of unknown gases.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, CONFINED SPACE, WORK RULES, CONSTRUCTION, GAS, SCBA, MANHOLE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 624452 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.