Accident Summary Nr: 14322424 - Employee dies of severe burns from explosion and fire

Accident Summary Nr: 14322424 -- Report ID: 0317500 -- Event Date: 05/27/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10715557406/01/199450930Rose Equipment

Abstract: Employee #1 was using a cutting torch with propane and oxygen when a flashback occurred, resulting in an explosion. The employee's clothes caught on fire. Employee #1 suffered burns to 93 percent of his total body surface and died.

Keywords: BURN, CLOTHING, OXYGEN, FIRE, TORCH, EXPLOSION, PROPANE, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107155574 Fatality Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.