Accident Summary Nr: 14320691 - CRUSHED BY FALLING BREAST ROLL ASSEMBLY

Accident Summary Nr: 14320691 -- Report ID: 0317000 -- Event Date: 01/23/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
85770601/24/198526760Scott Paper Company Chester Operations

Abstract: A PAPER MACHINE BREAST ROLL ASSEMBLY WAS BEING REINSTALLED ON A PAPER MACHINE. THE ASSEMBLY WEIGHED 24,500 POUNDS, AND WAS BEING LIFTED INTO PLACE BY AN AIR MOTOR WINCH SYSTEM. THE EMPLOYEES ENCOUNTERED AN OBSTRUCTION DURING THE LIFTING PROCESS, SO AN ENGINEER (EMPLOYEE #1) POSITIONED HIMSELF TO MEASURE THE OBSTRUCTION. THE SUPPORT ( LIFTING) SYSTEM FAILED AND THE BREAST ROLL ASSEMBLY FELL, PINNING EMPLOYEE #1 BETWEEN THE PAPER MACHINE AND THE ASSEMBLY. HE WAS CRUSHED TO DEATH. THE BREAST ROLL SHOULD HAVE BEEN BLOCKED UP BEFORE THE EMPLOYEE WAS ALLOWED INTO THE HAZARDOUS AREA.

Keywords: MAINTENANCE, BLOCKS, WORK RULES, CRUSHED, STRUCK BY, FALLING OBJECT, PAPER MACHINE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 857706 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close