Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14319941 - Employee killed when caught between scissor lift components

Accident Summary Nr: 14319941 -- Report ID: 0316700 -- Event Date: 10/28/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
12318013510/31/199434410Greiner Industries, Incorporated

Abstract: Employee #1 was operating a scissor lift on which the safety latches had been broken off from the control levers. He leaned over the front of the lift platform, inadvertently contacting the control levers and raising the platform. His upper body was crushed between the lift railing and an overhead crane rail. Employee #1 died.

Keywords: SAFETY LATCH, INADEQUATE MAINT, WORK RULES, CONTROL LEVER, CAUGHT BETWEEN, CRUSHED, OVERHEAD CRANE, AERIAL LIFT CONTROLS, AERIAL LIFT, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123180135 Fatality Other Millwrights

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.