Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14310478 - Employee killed when struck by saw chain segment

Accident Summary Nr: 14310478 -- Report ID: 0213600 -- Event Date: 06/25/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10734849206/29/199373590All County Equipment & Supply, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10734812007/01/199316230Monroe Roadways, Inc.

Abstract: Employee #1 was enlarging an existing hole in the top of a manhole cover when the diamond segmented chain on a Maxcut 12 saw broke and projected a diamond segment into his chest. The segment fractured his sternum and severed his aorta. Employee #1 died. The pneumatic powered concrete saw was manufactured by Spitnas, type 510090000, Masch. NR. 914141.

Keywords: MANHOLE COVER, EQUIPMENT FAILURE, SAW, CHEST, HEART, SEVERED, CONSTRUCTION, STRUCK BY, ARTERY, FLYING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107348492 Occupation Not Listed
2 107348120 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.