Accident Summary Nr: 14307490 - Two employees killed, two hospitalized, by collapsing boom

Accident Summary Nr: 14307490 -- Report ID: 0214200 -- Event Date: 01/19/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10048871701/20/198817710Politis Construction Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10048874101/20/198817710Vergona Crane Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10048871701/20/198817710Politis Construction Company, Inc.

Abstract: Employees #1, #2, #3, and #4 were having an afternoon break on the third level of a poured concrete construction job. At the same time, a crane over their heads was moving a load of plywood for forms over their heads when its boom collapsed. Employees #1 and #2 were struck and killed. Employees #3 and #4 required hospitalization. Investigation revealed that a gantry sheave pin had sheared in half from lack of lubrication, which allowed the boom to fall forward, taking up slack in the boom cable. The cable broke once the slack was gone, allowing the boom to fall from the boom cable. The cable had been scheduled for replacement but this had been delayed due to the tight construction schedule. Also, the crane was being operated with one of its boom stops removed.

Keywords: CONCRETE FORM WORK, COLLAPSE, INADEQUATE MAINT, PIN, CRANE BOOM, BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, STRUCK BY, SHEARED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100488717 Hospitalized injury Fracture Occupation not reported
2 100488717 Hospitalized injury Strain/Sprain Occupation not reported
3 100488717 Fatality Fracture Occupation not reported
4 100488741 Occupation Not Listed
5 100488717 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.