Accident Summary Nr: 14303101 - Employee injured when struck by falling steel tubing

Accident Summary Nr: 14303101 -- Report ID: 0155010 -- Event Date: 05/07/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
12442237905/07/199650510Capitol Steel & Supply Co., Inc.

Abstract: At approximately 8:45 a.m. on May 7, 1996, Employee #1 hitched a 3,246 lb bundle of steel tubing to a 10-ton gantry crane. The bundle contained 25 sections of 2 inch by 2 inch by 24 feet long steel tubing. He was using a chain sling consisting of a master link with four shackles; two chains, each with a slip hook for choicer hitches; and two grab hooks that were used to shorten the chains to level (or balance) the load. Employee #1 completed the hitch, stepped aside, and signaled the crane operator to hoist the bundle. When the bundle had been lifted approximately 8 feet above the floor, one of the chains slipped out of its grab hook. That side of the bundle fell to the floor, striking Employee #1 on the hard hat and face. He was hospitalized.

Keywords: HEAD, HOISTING MECHANISM, UNSECURED, WORK RULES, SUSPENDED LOAD, EQUIPMENT FAILURE, STRUCK BY, SLING, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124422379 Hospitalized injury Cut/Laceration Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close