Accident Summary Nr: 14300651 - CRANE BOOM COLLAPSE

Accident Summary Nr: 14300651 -- Report ID: 0951510 -- Event Date: 12/03/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
263561312/03/198517960Hawaiian Crane & Rigging Ltd

Abstract: ON DECEMBER 3, 1985, AT APPROXIMATELY 10 AM., A CREW OF 18 WORKERS WAS LIFTING A WIND TURBINE TO THE TOP OF A 114 1/2' HIGH TOWER, USING A 200 TON TRUCK MOUNTED CRANE WITH A 180 FOOT LONG BOOM. THE LOAD WEIGHT WAS APPROXIMATELY 44 TONS. WEATHER CONDITIONS WERE CLEAR WITH GROUND WINDS MEASURED AT 20 - 25 MPH, WITH GUSTS TO 30 MPH. THE OUTRIGGERS WERE FULLY EXTENDED AT 24', SET ON SOLID GROUND OVER STEEL ROAD PLATES. THE LIFT WAS MADE OVER "THE REAR", WITH 4 TAG LINES IN USE. THE BOOM ANGLE WAS 80 DEGREES, WITH A 35 FOOT RADIUS. AFTER REACHING THE TOP OF THE TOWER THE LOAD WAS SWUNG TO THE RIGHT, OVER "THE SIDE", AND HELD. THE CRANE OPERATOR WAS SIGNALLED TO BOOM UP WHEN THE CRANE STARTED TO TIP. THE BOOM AND LOAD FELLTO THE LEFT, AWAY FROM THE TOWER. THE LOAD CABLES GLANCED OFF THE TOWER. THE LOAD WAS RELEASED TO PREVENT THE CRANE FROM TIPPING. THE BOOM AND LOAD COLLAPSED TO THE GROUND. THREE HIGH VOLTAGE 4 KV ELECTRIC LINES WERE STRUCK AND BROKEN AT THE JOB SITE PERIMETER. SOME HEAVY EQUIPMENT DAMAGE OCCURRED. NO WORKERS WERE INJURED.

Keywords: OUTRIGGER, COLLAPSE, TRUCK CRANE, CRANE, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 2635613

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close