Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 14297402 - Employee's hands amputated in power press

Accident Summary Nr: 14297402 -- Report ID: 0352420 -- Event Date: 03/04/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10202889103/11/198623960Acme Pad Corporation

Abstract: Employee #1 was attempting to adjust a hydraulic power press when it activated, catching both of her hands in the point of operation and amputating them. The point of operation was provided with a barrier guard. It had been adjusted, however, to a height that allowed the operator to reach under the guard and have her hands in the point of operation when the machine cycled.

Keywords: MAINTENANCE, AMPUTATED, POWER PRESS, GUARD, WORK RULES, LOCKOUT, POINT OF OPERATION, HYDRAULIC PRESS, PRESS OPERATOR, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102028891 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.